English Japan
Call Us: +92 423 5314521-2
Email: info@mgheng.com
COMPANY FIKE FIRE SYSTEMS CCTV SYSTEMS ACCESS CONTROL SCHRACK FIRE SYSTEMS
FIRE SUPRESSION
|
FIRE DETECTION
|
FIRE ALARM
|
EXPLOSTION PROTECTION
| INTEGRATION
 
In addition to our high quality range of products, we also offer a wide range of services such drawing up security concepts and system-based solutions. The development of reliable fire alarm systems has a tradition. Considerable investment in research and development, as well as representation in international bodies and co-operation with technical universities, fire prevention bodies, fire brigade associations and testing institutes guarantee that our products are not only able to boast cutting edge technology, but that they also assume a pioneering role in working to ensure the security of people and valuables.
 
Integral Loop technology
Security The permanent, intelligent communication between the control panel and detectors (modules) occurs with the highest level of transmission security and enables continuous monitoring and evaluation of the current status of the system. A fault in the wiring network or false alarms due to electromagnetic disturbances e.g. radio wave interference, overvoltage, glitches etc., are localised from the control panel and are automatically filtered out using redundant coding with the ability to detect faults.
MTD 533 Multiple Sensor Detector
The MTD 533 can be used as a smoke detector, as a heat detector or as a combined smoke/heat detector as well, and is programmed and set-up specifically for the environmental conditions that it is part of. The MTD 533 detects smouldering fires and open fires at an early stage by being able to detect and evaluate the characteristics of the fire´s smoke (by means of the Tyndall principle) as well as heat (NTC sensor principle).
Manual Call Point MCP 535
The Manual Call Point MCP 545 is used to manually trigger a fire alarm (Type A in compliance with EN 54-11). The detector is fitted with an integrated short circuit isolator as standard...
Ventilation duct detector LKM 531

* Simple installation in all types of ventilation ducts
* Aspirating pipe can be optimally adapted to suit any duct
* Alarm LED on the detector is visible through the transparent case cover
* Inspection and corrective maintenance processes do not require any tools
* Detector can be checked in its fitted state
* Optimal flow dynamics
* No airflow indicator/ airflow monitor required
* Integrated short circuit isolator
* VdS-approval

Loop siren BA-SOL
Loop siren BA-SOL is an addressable device for the optical and acoustical signalisation of a fire alarm, suitable for the direct connection on the loop.
Loop flashlight BA-FOL
Loop flashlight BA-FOL is an addressable device for the optical and acoustical signalisation of a fire alarm, suitable for the direct connection on the loop.
Base siren SBL 501
* Reduced installation costs
* Detector base and siren on the same installation place
* Up to 32 sirens can be controlled simultaneously per loop
* 3 warning tones can be set DIN-tone, slow whoop, continous tone
* 2 settable volume strengths
* Very low current consumption (< 4mA)
* Integrated short circuit isolator
* VdS approval
* Pursuant to EN 54-3 and EN 54-17
Plattform siren SBL 502
* Up to 32 sirens can be controlled simultaneously per loop
* 3 warning tones can be set DIN-tone, slow whoop, continous tone
* 2 settable volume strengths
* Very low current consumption (< 4mA)
* Integrated short circuit isolator
* VdS approvaL
* Pursuant to EN 54-3 and EN 54-17
* Available in red or white
Input/Output Module BAOI3
The Input/Output Module BA-OI3 contains a relay output with a programmable fail-safe position, two inputs for querying potential-free contacts ...
Input/Output module BA-IOM
The Input/Output module BA-IOM is used, for amongst other things, to control monitored devices, which are supplied with power by an external power supply (e.g. sirens etc.)...
Relay module BA-REL4
The relay module BA-REL4 contains 4 relays each containing a potential-free double-throw contact with a fail-safe position and an integrated short circuit isolator,...
Input module BX-AIM
The input module BX-AIM is used to connect threshold detectors to the loop technology or as a branch unit for monitoring hazardous areas...
Input module BA-IM4
The input module BA-IM4 contains 4 inputs for the monitored and non-monitored querying of potential-free contacts, as well as an integrated short circuit isolator...
 
 
© 2011 MGH Engineering & Control (Pvt.) Ltd.